Page 94 - Glow Insulation Product Guide
P. 94

ACOUSTICS
Acoustic Batten JCW 50C CONCRETE FLOOR BATTEN
02
06
01
04
05 02
01 18mm t&g chipboard @ 400mm centres or 22mm t&g chipboard at 600mm centres
02 Acoustic Batten JCW 50C
03 JCW L Shaped or Flat Perimeter Edging
Strip detail
04 40mm min directly applied sand & cement or proprietary screed (min 80kg/2m)
05 150mm (min) Concrete Floor
06 Metal Ceiling System with 100mm (min) void and 1 layer of 8kgs/m2 gypsum based board
Note:
types as illustrated.
03
FFT-3 Resilient Composite Standard Batten: Timber Batten laminated to a 9mm acoustic resilient layer
Robust Detail (Registered Sites)
•
that meets the Robust Detail requirements. Pre-completion testing is not required
• Acoustic Batten JCW 50C = FFT-3 Floating Floor Types; E-FC-1,2,7 and E-FS-1 (screed layer varies based
PCT/PT & Refurbishment
•
• It is essential all components are correctly installed and detailed to meet the requirements where Pre-completion Sound Testing is required
•
(services between battens must not penetrate resilient layer)
• Ideal for good impact sound improvement where height permits
•
Size: 50mm x 42mm x 1800mm Weight: 1.2 kgs - Other batten sizes are available on request
Robust Detail Performance: Reduction in Impact Sound Transmission: rd ∆ Lw = 28 dB
Tests were carried out by Building Research Establishment Ltd, UKAS accredited test laboratory No. 0578 on December 3rd 2013. Test Report No. 291911.
Method of Compliance
Robust Detail, PCT/PT (Scotland)
Ancillary Products
JCW Flat Edging Strip (50 Lm x 150mm x 5mm) JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre)
JCW Acoustic Sealant (310ml)
94
www.glowinsulation.co.uk