Page 91 - Glow Insulation Product Guide
P. 91

PIR (GROUND FLOOR)
1 - Sand blinding and hardcore
2 - Radon barrier / DPM
3 - Quinn Therm QF boards
4 - Quinn Therm edge insulation 5 - Concrete slab on separating
layer
6 - Timber flooring on polyethylene slip sheet layer
U-value results below based upon wall construction shown:
6
5
4 3
2
1
Radon barrier / DPM; Quinn Therm
QF; 150mm concrete; timber
flooring (floor finish omitted);
150mm depth of Quinn Therm QF
vertical edge insulation. Calculations
performed to BS EN ISO 6946 and BS EN ISO 13370, taking account of repeating thermal bridges.
Required thickness of Quinn Therm QF
Perimeter / Area ratio
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
thickness (mm)
50 60 70 75 80 90
100 110 120 125 140 150 160 180 200
0.15 0.21 0.24 0.14 0.19 0.21 0.13 0.17 0.19 0.12 0.16 0.18 0.12 0.16 0.18 0.12 0.15 0.16 0.11 0.14 0.15 0.10 0.13 0.14 0.10 0.12 0.13 0.10 0.12 0.13 0.09 0.11 0.12 0.09 0.10 0.11 0.08 0.10 0.11 0.08 0.09 0.10 0.07 0.08 0.09
U-value (W/m 2K)
- - -
0.23 0.24 0.25 ----
- - - -
0.21 0.22 0.23 0.20 0.21 0.21 0.19 0.20 0.21 0.18 0.18 0.19 0.16 0.17 0.17 0.15 0.16 0.16 0.14 0.15 0.15 0.14 0.14 0.14 0.13 0.13 0.13 0.12 0.12 0.12 0.11 0.12 0.12 0.10 0.10 0.11 0.09 0.10 0.10
0.23 0.24 0.22 0.22 0.21 0.21 0.19 0.19 0.18 0.18 0.16 0.16 0.15 0.15 0.15 0.15 0.13 0.13 0.13 0.13 0.12 0.12 0.11 0.11 0.10 0.10
0.24 0.24 0.23 0.23 0.22 0.22 0.20 0.20 0.18 0.18 0.17 0.17 0.15 0.16 0.15 0.15 0.14 0.14 0.13 0.13 0.12 0.12 0.11 0.11 0.10 0.10
www.glowinsulation.co.uk 91